1. Overview
AN1910 magneto-resistive speed sensor adopts high sensitivity magneto -resistive elements and is embedded with magnetic sensitive elements to implement non-contact speed measurement. As the measured object moves, the sensor outputs square wave level signals that change with rotational frequency ratio. The two-channel sensor outputs two-channel square wave (TTL level) signals with a phase difference, based on which the running direction of equipment can be determined.
2. Functions
● The object of measurement is a rotary ferromagnetic material body, including gears, racks, cams and special male and female faces;
● Square wave pulse (TTL level) signals are output, which change with the clearance of magnetic conductive material and magnetic material (fluted disc and key slot, etc.);
● The sensor applies to precision measurement of speed (positive and negative operation).
3. Features
● Non-contact measurement; the installation clearance is larger than that of common magneto-electric speed sensors and eddy-current sensors (0-5mm);
● Embedded with high-sensitive magneto-resistive elements, through which square wave signals are output directly, and high immunity from environmental disturbance is realized;
● Short-circuit protection and polarity protection;
● Fully sealed structural design; capable of working under water and oil.
4. Application
Speed measurement of various large rotary machines (steam turbines, fans, pumps, compressors, centrifugal machines, and water turbines, etc).
5. Technical Specifications
● Frequency range:
Single channel: 0 ~ 30KHz
Double channel: 0 ~ 10KHz
● Output signal:
Appropriate to TTL level signals; high-level voltage is similar to supply voltage (VT), while low level is not greater than 0.3V.
● Power supply:
Voltage: 5 ~ 28VDC (recommended: 12VDC);
Power consumption: ≤10mA.
● Physical property:
Mounting thread:
Single channel: M10×1
Double channel: M16×1 (customizable);
Bearing length:
Single channel: 50mm
Double channel: 75mm (customizable);
Installation clearance:
Single channel: 1.5mm;
Double channel: 2.5mm;
Weight: 100g (excluding cables and lengthened type).
● Outlet method:
Single channel: Direct outlet, 3-core (power supply, common and signal terminals);
Double channel: 4-core aviation plug output (power supply, common, signal A and signal B terminals).
● Environmental restrictions:
Temperature: -40℃ ~ +75℃ (- 40oF ~ +167 oF)
Can work under oil and water.
● Executive standards
The United States Petroleum Association Standard: API 670
Safety certificate: CE;
Protection level: IP65;
Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4
Anti-electromagnetic interference: EMC/LVD
Refer to EN55011\ EN 61010\ EN50081\EN50082.
6. Ordering information
AN1912--Double channel, metric M16X1 mounting threads;
AN1911--Single channel, metric M10X1 mounting threads, direct outlet;
AN1911- AXX-BXX-CXX-DXX-00-FXX
AN1912- AXX-BXX-CXX-DXX-EXX-FXX
Standard model:
Single channel: AN1911--05-05-05-00-00-00
Double channel: AN1912--05-07-05-01-01-00
A: Unthreaded length:
05--5mm
Increased by 5mm (0.1in) on order;
Maximum unthreaded length is 20mm/0.8in less than probe bearing;
Minimum unthreaded length is 0mm; maximum unthreaded length: 200mm (8in).
B: Threaded bearing length:
05--50mm
07--75mm
Overall bearing length is increased by 5mm/0.1in;
Overall bearing length is 250mm/10in maximally, and 25mm/1in minimally.
C: Cable length
03--3m
05--5m
xx--Others
D: Outlet method:
00--Direct outlet
01--Aviation plug outlet
E: Armoured
00—Unarmoured
01--Armoured
F: Environmental restrictions
00--No requirement
01--Anti-hazard ATEX: Ⅱ1 G Exia ⅡC T4