PRODUCTS Products
Monitor system
项目名称: AN3550
担保机构: AN3550 series speed monitoring receives signals from a magneto-electric tachometric sensor or Proximity sensor; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are t... 还款方式: AN3550 series speed monitoring receives signals from a magneto-electric tachometric sensor or Proximity sensor; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device speed.2. Purposesl Online monitoring and protection of rotary machine speed;l Zero-speed survey control;l Over-speed protection;l Key-phase signal output.3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embedded microcontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l High/low velocity measuring systems implement precision measurement of zero and low (turning) speed.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Water turbines;l Air blowers;l Coal breakers;l Electromotor;l Rotary machines like fans.6. Technical Specificationsl Sensors:Magneto-electric sensor: Passive, outputting pulse signals changing with speed frequency;Mounting clearance: 1mm±0.2mm.Magneto-resistive sensor:Passive, outputting TTL level signals changing with speed frequency;Mounting clearance: 2.0mm±0.5mm.Proximity sensor: Φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.Note:Mounting clearance is determined based on a 1mm mechanical distance between tooth crest and probe or -10VDC output voltage of preamplifier; mechanical distance is firstly considered so as to prevent the probe from being damaged due to the eccentric shaft.l Measuring rangeOver-speed protection/standard speed:Range: 0-9999rpmPrecision: ±0.5%±1 rpmZero speed:Range: 0-99.99rpmPrecision: ±0.5%±0.01 rpmKey phase:Output square (TTL) level signalNote: Range can be set by field programming.l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC (185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤ 5W.l Standard signal output:Active 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1kg.l Way of installation:Open hole installation:Hole size: 152 (W) × 76 (H) mm, 6.0(W) ×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationAN3551/52/53- speed/zero speed/key phaseAN3551- AXX-BXX-CXX-DXX-EXX-F02-GXXAN3552- AXX-BXX-CXX-DXX-EXX-F02-GXXAN3553- AXX-BXX-CXX-DXX-EXX-F02-GXX Standard Configuration Model:Revolution speed: AN3551-00-00-00-00-00-02-60 (assorted with AN1920 sensor)Zero speed: AN3552-01-00-00-00-00-02-60 (assorted with AN1920 sensor)Key phase: AN3553-02-02-00-00-00-02-01 (assorted with AN1808 Proximity Sensor)A: Range limit00--0 ~ 9999rpm (standard)01--0 ~ 99.99rpm (zero speed)02--Square wave phase signal output (key phase)Note: Range can be set by field programming.B: Sensor type:00--AN1920 passive magneto-electric sensor01--AN1910 active magneto-resistive sensor02--AN1808 Proximity sensor (φ8 probe)xx--OthersNote:It is recommended that magneto-electric probe be used for over-speed/revolution speed/zero-speed protectors, with speed measurement of multi-tooth fluted disc, and active magneto-resistive or eddy-current probe be used for key-phase protector (φ8 probe).C: Relay output (DPDT):00--Double dry contact output (Alert, Danger)01--Single dry contact output (Alert)02--No relay outputD: Standard signal output:00--4 ~ 20mA standard current output01--1 ~ 5V standard voltage output02--RS 485 communication interface outputE: Power supply00--24VDC (18 ~ 36V)01--220VAC02--110VACF: Way of installation00--Guide rail installation DIN35mm01--Base plate installation02- Open hole installationG: Tooth number (key or slot number)01--160--60XX--Others (represented by a figure)Note: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN3560
担保机构: AN3520 series shaft position monitoring receives signals from a Proximity sensor (shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then ident... 还款方式: AN3520 series shaft position monitoring receives signals from a Proximity sensor (shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device shaft position.2. Purposesl Online monitoring and protection of rotary machine shaft position; l Online monitoring and protection of rotary machine expansion difference;3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l A key quickly sets the direction of the sensor(Stay away from the positive direction Or close to positive direction)l Intelligent fast initial zero setting, easy to debugl Digital quick debugging5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Air blowers;l Rotary machines like Water turbines.6. Technical Specificationsl Sensors:Proximity sensor: Proximity probe: Φ8 /Φ11 /Φ25 /Φ50 probeShaft position:2mm: 7.87mV/μm (200mV/mil)4mm: 3.94 mV/μm (100mV/mil)25mm: 0.394 mV/μm (10mV/mil)Expansion difference:12mm: 0.787mV/μm (20mV/mil)25mm: 0.394 mV/μm (10mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Shaft position: 2.00/4.00mm; Resolution: 0.01mm;Precision: 0.5%±0.01mm.Expansion difference: 12.00/25.00mm; Resolution: 0.01mm;Precision: 0.5%±0.01mm.l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC (185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤5W.l Standard signal output: Standard currentActive 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1kg.l Way of installation:Open hole installation:Hole size: 152 (W) ×76 (H) mm,  6.0(W)×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationAN3561/62- Shaft position/ Expansion differenceAN3561- AXX-BXX-CXX-DXX-EXX-F02AN3562- AXX-BXX-CXX-DXX-EXX-F02Standard Configuration Model:Shaft position: AN3561-00-00-00-00-00-02 (assorted with AN1808 sensor)AN3561-01-01-00-00-00-02 (assorted with AN1811 sensor)AN3561-03-03-00-00-00-02 (assorted with AN1850 sensor)Expansion difference:AN3562-02-02-02-00-00-02 (assorted with AN1825 Proximity Sensor)A: Measuring range00—2.00m(φ5/φ8 probe) 01-- 4.00m(φ11 probe)02-- 12.00m(φ25 probe)03-- 25.00m(φ50 probe)xx--OthersB: Sensor type:00-- AN1808 Proximity sensor(φ8 probe)01--AN1811 Proximity sensor(φ11 probe)02-- AN1825 Proximity sensor(φ25 probe)03-- AN1850 Proximity sensor(φ50 probe)xx--OthersC: Relay output (DPDT):00--Double relay dry contact output (high - low - Alert and high high - low low- Danger)01--Single relay dry contact output (high - low - Alert or high high - low low- Danger)02-- Double relay dry contact output (high - Alert and high high - Danger)03--No relay outputD: Standard signal output:00--4 ~ 20mA standard current output00--1 ~ 5V standard voltage output02--RS 485 communication interface outputxx--OthersE: Power supply00--24VDC (18 ~ 36V)01--220VAC02--110VACxx--OthersF: Way of installation00-- DIN-rail mount: DIN35mm01-- Panel mount02-- Open hole installationNote: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN3580
担保机构: AN3580 series dual vibration monitoring receives signals from two magnet-electrical vibration velocity Sensors(Bearing vibration) or Proximity sensors(shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are tran... 还款方式: AN3580 series dual vibration monitoring receives signals from two magnet-electrical vibration velocity Sensors(Bearing vibration) or Proximity sensors(shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device Vibration.2. Purposel Online monitoring and protection of rotary machine bearing vibration;l Online monitoring and protection of rotary machine shaft vibration;l Online monitoring and protection of rotary machine Throw.3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Motorsl Water pumps;l Gearboxsl Water turbines;l Air blowers;l Coal-breaker;l Coal-mill;l Rotary machines like fans.6. Technical Specificationsl Sensors:Magneto-electric Velocity sensor: Inertial sensor, no power supply, Sensitivity: 20mV/mm/S (500mV/in/s).Piezoelectric acceleration sensor: ICP type, 24V / 4mA constant current source power supply Sensitivity: 100mV/gPiezoelectric velocity sensor: ICP type, 24V / 4mA constant current source power supply Sensitivity: 4mV/gProximity sensor: Φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Displacement: 0~999μm(Pk-Pk); Resolution: 1μm; Precision: 0.5%±1μm.Velocity: 0~99.9mm/S(rms); Resolution: 0.01mm/S; Precision: 0.5%±0.01mm/S.Acceleration: 0~9.99g(Pk); Resolution: 0.01g; Precision: 0.5%±0.01g.l The frequency range Piezoelectric Sensor: 0.5~15KHz;Magneto-electric Sensor:Standard: 10~1000HzLow frequency: 5~1000Hz  Ultra-low frequency: 0.5~100Hz;Proximity Sensor:0~10 KHz;l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC(185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤5W.l Standard signal output: Standard currentActive 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1.2kg.l Way of installation:Open hole installation:Hole size: 152 (W) × 76 (H) mm, 6.0(W) ×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670;Safety certificate: C E;Protection level: IP56;Anti-electromagnetic interference: EMC\ LVD;Refer to EN55011\ EN 61010\EN50081\EN500827. Ordering informationAN3581/82/83—Bearing vibration / shaft vibration / Turbine throwAN3581- AXX-BXX-CXX-DXX-EXXAN3582- AXX-BXX-CXX-DXX-EXXAN3583- AXX-BXX-CXX-DXX-EXXStandard Configuration Model:Bearing vibration: AN3581-00-00-00-00-00Shaft vibration: AN3582-00-01-00-00-00Turbine throw: AN3583-00-01-00-00-00A: The monitor range:00—Displacement: 0~999μm(Pk-Pk)01—Velocity: 0~99.9mm/s(rms)02—Acceleration: 0~9.99g (Pk)B: External sensor type:00—Magneto-electric Velocity sensor01—Proximity Probe sensor( probe with φ8 or φ5 diameter)02—Ultra-low frequency magneto-electric speed sensor03—Piezoelectric acceleration sensor04—OtherC: Relay output( DPDT):00— 2 relay output(Alert, Danger)01— 1 relay output(Alert)02— No relay outputD: Standard signal output:00— 4~20mA standard current output01— 1~5V standard voltage output02— RS 485 communicate interface outputE: Power supplier:00—220VAC01—24VDC02—110VAC      03—OtherNote: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1808
担保机构: 1. Overview: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1808 Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measur... 还款方式: 1. Overview: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1808 Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN18088mm proximity   Sensor system follows the 670 Standard made by AmericanPetroleum Institute (API) for this kind of Sensor completely. All AN1808 8mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. TheSensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN18008mm proximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN18008mm proximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1800 8mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1800 8mm proximitor: any wiring fault of supply terminal, common terminal (SG) and output terminal can not damage the proximitor, and it has the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN 1808 8mm probe are connected through mechanical deformationto ensure its stability and reliability in severe environment.Forall connectors of AN 1808 8mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification of the U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectorsat two ends of AN1880 extension cable are different. The connector withmale thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 2.0mm (80mil)Linear range is from the position about 0.25mm (10mil) from surface of the target: 0.25~2.3mm (10~90mil).l Sensitivity: 7.87mV/μm (200mV/mil)Thesensitivity is less than 7.87mV/μm (200mV/mil) ±5% within the linear range of 2.0mm (80mil) including interchangeability error.l Probe installation clearance: 1.25mm (50mil).l Frequency response:0~10KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring.l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA.l  Requirements for target:Diameterof target (width of toroid): 16mm (0.6in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Shaft diameter: minimum 50mm (2in), 76mm (3in) recommend; pay attention to installation distance between probes to avoid mutual effect when diameter is less than 50mm, and ensure the distance is no less than 40mm (1.6in).Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent.l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%;l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site.l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 15N.mReversely installed probe: 7.5 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering informationl AN1808 8mm standard proximity probe Metric system: AN1808/M   M10x1 threadAN1808/M-AXX-BXX-CXX-DXX-EXXBritish system: AN1808/I   3/8″-24UNF threadAN1808/I-AXX-BXX-CXX-DXX-EXXStandard model:AN1808/M-00-05-10-00-00AN1808/M-00-05-50-00-00AN1808/M-00-05-90-00-00AN1808/I-00-05-10-00-00AN1808/I-00-05-50-00-00AN1808/I-00-05-90-00-00A: Unthreaded length00—0mm / 0 in05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 20mm/0.8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 in03-30mm/ 1.2in (housing size of reversely installed probe)Total housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - unarmored01 - armoredE: Approval institution00 - no requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – otherl AN1808 8mm reversely installed proximity probe Metric system: AN1808/MR M10x1 thread; unthreaded length: 5mm; total housing length: 30mm.AN1808/MR-05-30-CXX-DXX-EXXBritish system: AN1808/IR 3/8″-24UNF thread; unthreaded length: 0.2in; total housing length: 1.2in.AN1808/IR-02-12-CXX-DXX-EXXStandard model:AN1808/MR-05-30-10-00-00AN1808/MR-05-30-50-00-00AN1808/MR-05-30-90-00-00AN1808/IR-02-12-10-00-00AN1808/IR-02-12-50-00-00AN1808/IR-02-12-90-00-00C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - unarmored01 - armoredE: Approval institution00-No requirement01-ATEX: Ⅱ1 G Exia ⅡC T4       XX - other l AN1800 8mm proximitorAN1800-08-BXX-CXX-DXXStandard model:AN1800-08-05-00-00AN1800-08-09-00-00B: total cable length (probe + extension cable)05—5m09—9mC: installation mode00 - DIN35mm guide rail installation01 – Base plate installationD: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A: cable length40—4m45—4.5m80—8m85—8.5mB: cable options00 - Unarmored01 - ArmoredC: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX –Other
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1811
担保机构: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1811  Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surfa... 还款方式: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1811  Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN1811 11mmproximity   Sensor system follows the 670 Standard made by American Petroleum Institute (API) for this kind of Sensor completely. All AN1811 11mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. TheSensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN180011mm proximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN180011mm proximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1800 11mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1800 11mm proximitor: any wiring fault of supply terminal, common terminal (SG) and output terminal can not damage the proximitor, and it has the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN 1811 11mm probe are connected through mechanical deformation to ensure its stability and reliability in severe environment.For all connectors of AN 1811 11mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification ofthe U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectors at two ends of AN1880 extension cable are different. The connector with male thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 4.0mm (160mil)Linear range is from the position about 0.50mm (20mil) from surface of the target: 0.50~4.50mm (20~200mil). l Sensitivity: 3.94mV/μm (100mV/mil)Thesensitivity is less than 3.94mV/μm (100mV/mil) ±5% within the linear range of 4.0mm (160mil) including interchangeability error. l Probe installation clearance: 2.50mm (100mil). l Frequency response:0~8KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring. l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA. l  Requirements for target:Diameterof target (width of toroid): 30mm (1.2in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Shaft diameter: minimum 76mm (3in), 150mm (6in) recommend; pay attention to installation distance between probes to avoid mutual effect when diameter is less than 76mm, and ensure the distance is no less than 65mm (2.6in).Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent. l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%; l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site. l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.        Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 15N.mReversely installed probe: 7.5 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass. l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering information l AN1808 8mm standard proximity probe Metric system: AN1808/M   M10x1 threadAN1808/M-AXX-BXX-CXX-DXX-EXXBritish system: AN1808/I   3/8″-24UNF threadAN1808/I-AXX-BXX-CXX-DXX-EXXStandard model:AN1808/M-00-05-10-00-00AN1808/M-00-05-50-00-00AN1808/M-00-05-90-00-00AN1808/I-00-05-10-00-00AN1808/I-00-05-50-00-00AN1808/I-00-05-90-00-00A: Unthreaded length00—0mm / 0 in05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 200mm/8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 in03-30mm/ 1.2in (housing size of reversely installed probe)Total housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Otherl AN1808 8mm reversely installed proximity probe Metric system: AN1808/MR M10x1 thread; unthreaded length: 5mm; total housing length: 30mm.AN1808/MR-05-30-CXX-DXX-EXXBritish system: AN1808/IR 3/8″-24UNF thread; unthreaded length: 0.2in; total housing length: 1.2in.AN1808/IR-02-12-CXX-DXX-EXXStandard model:AN1808/MR-05-30-10-00-00AN1808/MR-05-30-50-00-00AN1808/MR-05-30-90-00-00AN1808/IR-02-12-10-00-00AN1808/IR-02-12-50-00-00AN1808/IR-02-12-90-00-00C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00-No requirement01-ATEX: Ⅱ1 G Exia ⅡC T4XX - Other l AN1800 8mm proximitorAN1800-08-BXX-CXX-DXXStandard model:AN1800-08-05-00-00AN1800-08-09-00-00B: total cable length (probe + extension cable)05—5m09—9mC: installation mode00 - DIN35mm guide rail installation01 –Base plate installationD: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A:Cable length40—4m45—4.5m80—8m85—8.5mB: Cable options00 - Unarmored01 - ArmoredC: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other
项目规模: 0 项目期限: 0 个月 年化收益: